Impact-resistant Fiber Cement Composite Steel Plate

Impact-resistant fiber cement composite steel plate is primarily used in harsh environments. The primary impact-resistant component is the galvanized steel sheet layer.
ផ្ញើរសំណួរ
ការណែនាំផលិតផល

Impact-resistant fiber cement composite steel plate is primarily used in harsh environments. The primary impact-resistant component is the galvanized steel sheet layer. The 0.5mm galvanized steel sheet is perforated on both sides with a 3-5mm perforation and a 10-20mm perforation spacing. This perforation enhances the mechanical bond with the cement core, providing excellent rigidity and impact resistance, while also preventing delamination during long-term use. Common specifications for impact-resistant fiber cement composite steel plate are 1200mm*2400mm*9.5mm, weighing approximately 25 kg/㎡. It has a bending strength of >=185 MPa, a moisture content of <=10%, and an A1 combustion rating. Its performance may vary depending on the keel and support system.

 

To effectively utilize impact-resistant fiber cement composite steel plate, it is important to understand not only its advantages but also its disadvantages, so we can effectively avoid them.

Its tensile strength can reach 2,348 MPa, and its light weight makes it extremely convenient and quick to install.

Fibers absorb impact energy through a bridging effect, withstanding impact velocities of 3.43 m/s under dynamic loads.

Impact-resistant fiber cement composite steel plates also have drawbacks during use:

The entire production process is complex, resulting in a long production time and significant cost increases.

Fiber cement can fracture under extreme loads, requiring uniform fiber dispersion.

Joints and fasteners require regular inspection, resulting in high maintenance costs.

 

When transporting impact-resistant fiber-cement composite steel plate, we must take care to avoid damage from vibration and collision. This includes instructions on packaging, tool selection, loading procedures, and unloading precautions:

 

Each sheet is covered with PE protective film to prevent scratches and wear of the galvanized coating from friction between the metal panels and other objects during transport.

 
 

A van is preferred. The specific method of transportation will depend on the road conditions, and there will be slight differences between long and short distances.

 
 

Air cushioning bags or cardboard should be used between the inner wall of the van and the stack of sheets to eliminate gaps and prevent the stack from swaying during transport.

 
 

Unloading is the final step in the transportation of impact-resistant fiber cement composite steel plate. Unloaded sheets must be immediately placed on a flat, dry surface free of sharp objects. They should not be placed outdoors or stacked on uneven surfaces.

 

As a manufacturer, we often receive calls from users asking how to choose the right impact-resistant fiber cement composite steel plate. The selection is actually quite simple; the key principle is to remember that the most suitable sheet is the best. Adjust the fiber type according to the application scenario to ensure that impact resistance meets the requirements. If the environment is humid or corrosive, increase the density of the cement matrix or apply an anti-corrosion coating to prevent rust on the steel plate.

Maintenance and care of impact-resistant fiber cement composite steel plates are crucial. It is recommended to inspect joint sealing and steel plate corrosion every two years and promptly repair micro-cracks. With normal maintenance, the service life is >=10 years. In extreme operating environments, the maintenance interval may need to be shortened.

 